The fault code check list below will give you an idea of what is going on with your Mitsubishi City Multi air conditioning system. Each fault code has a brief description, which will let you understand how serious the problem is. This is an easy-to-use and quick reference guide.
Of course, finding out what the fault code means is just the first step, but it will give you an idea of the issue. It may well happen that you will not be able to solve the problem on your own, so you will have to call technical support and book an engineer. In this case we recommend that you write down the Mitsubishi City Multi error code and tell this number to the tech support.

2001 Passport Owner's Manual. To purchase printed manuals, you can order online or contact: Helm Incorporated (800) 782-4356. To save paper and time, you can download the latest manuals now. Recommended Service for Your 2001 Honda Passport Recommendations for regular servicing tasks for your vehicle can be found in Service & Maintenance. 2001 honda passport repair manual download. Official Owners Manual for 2001 Honda Passport from the Honda Owners Site. A printed Owner's Manual, Navigation Manual, and Warranty Booklet are complimentary to the first registered owner, up to six months after vehicle purchase. Delivery time is approximately five weeks. To save paper and time, you can download the latest.

2012 mazda 5 manual. Motor Era offers service repair manuals for your Mazda 5 - DOWNLOAD your manual now! Mazda 5 service repair manuals. Complete list of Mazda 5 auto service repair manuals: Mazda 5 Premacy Sport Service Repair Manual 2005 2006 2007; Mazda 5 2005-2007 Service Repair Manual Download; Mazda 5 2005-2006-2007 Service Repair Manual. View and Download Mazda 5 manual online. 5 Automobile pdf manual download. Page 152 Authorized Mazda Dealer or a tire repair station. Do not ignore the TPMS Warning Light: Ignoring the TPMS warning light is dangerous, even if you know why it is illuminated. Dec 18, 2018  Here are a Mazda 5 workshop manuals – to the repair and maintenance of cars, which at any convenient time you can download for free at the following link. These Mazda 5 service manuals contains detailed information on how to diagnose various model faults and the subsequent necessary repair of components, assemblies and mechanisms of the car, provides.

News Blaupunkt Travelpilot Radio Code Generator Service Free Download. Sometimes you can feel break inside because of your unlock Mitsubishi Pajero radio code problem! Don’t need to be sorry 0. Mitsubishi Nativa Radio Code Generator Tool For Free. Radio Codes Calculator. Jul 17, 2019  How To Unlock a Mitsubishi Radio Code - Mitsubishi Radio Code Generator Download. How To Unlock a Mitsubishi Radio Code - Mitsubishi Radio Code Generator Download.

Mitsubishi electriс City Multi AC fault codes

Mitsubishi Adns Codes Downloads

FAULT
CODE
R22R4O7cR410ADESCRIPTION
403xxxComms fault between boards - check inverter error detail for which 2 boards, check transformer , bus voltage and inter-connecting cables
900---Lossnay unit in test run
1102xxxHigh compressor discharge temperature. Discharge temperature has exceeded 110°C or more. Short of refrigerant. Discharge thermistor
1111xx-Low pressure/temperature fault - check thermistors (TH2, TH3, TH4), gas charge, indoor fan, heat exchanger and filter
1112xx-
1113xx-
1202xxxPreliminary fault to 1102
1204--xPreliminary heat exchanger gas temperature sensor fault - check thermistors 10a and 10b
1205xxxPreliminary thermistor fault (TH5)
1211xx-Preliminary thermistor fault (TH2)
1214xxxPreliminary thermistor fault (THHS)
1216xxxPreliminary thermistor fault (TH7)
1217xxxPreliminary thermistor fault (TH8)
1219xx-Preliminary thermistor fault (TH9)
1221xxxPreliminary thermistor fault (TH6)
1243-x-Preliminary thermistor fault (TH10)
1301-x-Low pressure fault (63L operation) low pressure sensor sensing less than 1 bar immediately before starting
1302xx-High pressure fault - check pressure in system for more than 29 bar (R407c) 38 bar (R410A). Check high pressure sensor against gauge pressure
1368xx-Pressure sensor fault (PS1) at BC - compare pressure reading on SW1 on O/C
1370xx-Pressure sensor fault (PS3) at BC - compare pressure reading on SW1 at O/C
1402--xPreliminary fault to 1302
1500xxxSystem overcharge. Abnormal low compressor superheat - discharge thermistor TH4
1501xx-High compressor shell temp - check for shortage of gas, insufficient indoor index running (comms room units)
1505xx-Suction pressure abnormal - generated by low pressure sensor detecting a vacuum - check for blockage, closed valve or sensor fault
2500xxxDetecting lack of water flow on a water circuit
2502xxxI/C has water level in drip tray, when the unit was running in cooling (temperature sensors - check for open or closed circuit and operation of pump)
2503xxxI/C has water level in drip tray when the unit was running in cooling (float sensor - check for closed circuit on float switch and operation of pump)
2600x-xWater leak from humidifier
4100---Compressor over current protection on Mr Slim with M-net interface - check inverter or compressor
4101---
4102--xOpen phase fault - check power supply and noise filter for loss of phase, check wiring and fuses
4103xxxReverse phase fault - check phase rotation, loss of phase through the noise filter, fuse blown and high pressure switch open at power on
4106--xTransmission power supply fault - check wiring, high current, incorrect voltage on transmission line and/or M-Net board
4108-x-Over current protection on DOL compressor - check power supply, contactor and compressor
4115xxxPower supply abnormal - check power , fuses, connections and PCB
4116xxxFan motor abnormal - check fan motor and board (relates to indoor unit or Lossnay unit)
4124---Thermal switch (49C) open circuit on Mr Slim on M-Net - reset and check pressures and air flow
4210x--Compressor over current problem - check inverter balance. Compressor and inverter
4220-xxLow inverter board BUS voltage. Less than 289VdcDC is detected. - check mains supply
4225--xLow DC voltage on Vdc on fan inverter - check CNVdc for 300Vdc on diode stack and check mains power supply to outdoor unit
4230xxxHigh temperature on heat sink on inverter - check for blockages in air duct, failure of INV fan or failure of thermistor
4235--xFan inverter heat sink overheat protection. Reduced airflow through heat sink. Fan motor problem. THHS thermistor problem.
4240xxxOver current protection. If high current is detected for more than 10 minutes - check inverter balance. Reduced airflow through heat sink
4245--xOver current protection. Possible ACCT current sensor fault. Should read 280 ohms between pins 1 & 2 and across pins 3 & 4
4250--xOver current protection. Inverter IPM problem. Compressor lock - check inverter balance
4255--xInverter cooling fan problem - if high static fan is used then check that SW3-9
4260-xxPreliminary inverter heat sink overheat protection. Reduced airflow through heat sink. Fan motor problem. THHS thermistor problem.
5101xxxThermistor fault at indoor/outdoor unit - check fault code address
5102xxx
5103xxx
5104xxxThermistor fault at indoor/outdoor unit - check fault code address (indoor fault - check SW7-3 is off)
5105xxxTH5 open/short circuit - check if the TH is disconnected from the board
5106xxxTH6 open/short circuit - check if the TH is disconnected from the board
5107xxxTH7 open/short circuit - check if the TH is disconnected from the board
5108xx-TH8 open/short circuit - check if the TH is disconnected from the board
5109-x-TH9 open/short circuit - check if the TH is disconnected from the board
5110xxxTH10 open/short circuit - check if the TH is disconnected from the board
5111x-xBC box thermistor error - TH11 open/short circuit, disconnected from board/pipe
5112xxxBC box thermistor error - TH10 open/short circuit, disconnected from board/pipe
5113x--BC box thermistor error - TH open/short circuit, disconnected from board/pipe
5114x--
5115x-xBC box thermistor error - TH15 open/short circuit, disconnected from board/pipe
5116x-xBC box thermistor error - TH16 open/short circuit, disconnected from board/pipe
5201xxxPressure sensor fault outdoor unit/BC box - check fault code address/SW1
pressure sensor readings
5202x--Pressure sensor fault (PS2) in the BC box
5203xxxPressure sensor fault (PS3) in the BC box
5300---A-Control UH fault
5301-xxCurrent sensor fault, ACCT or DCCT - check inv. error details
5401--xTemperature sensor fault - check CN30 for humidity sensor
5701--xLoose float switch connector - check switch, check CN4F on indoor unit
6201--xTB7 transmission line communication error - check for voltage abnormality/short
6202--xTransmission processor hardware error - check for noise/short on M-Net cable
6600xxxRepeat address fault - two or more units are assigned the same address -
correct the repeated address
6601--xPolarity setting error - no voltage or short circuit on the m-net transmission line
6602xxxHardware error of transmission processor . Noise interference. Polarity problem on TB7
6603xxxBus circuit busy - check if indoor unit, Lossnay unit or anything else has been wired
into TB7, instead of TB3
6607xxxCommunication issue - no response back from unit whilst system is operational
6608xxxCommunication error - loss of voltage or noise entering the transmission line
6700---K control communication error - R22 type unit connected onto M-Net circuit comms error
6701---
6702---K control duplicate address error - two or more R22 type units connected onto
M-Net circuit with the same address
6750---K control communication error - R22 type unit connected onto M-Net circuit comms error
6751---R22 R/A thermistor fault (P1)
6752---R22 frost protection at I/C (P6)
6753---Comms fault between O/C and I/C
6754---R22 drain fault (P5)
6755---
6756---R22 frost protection at I/C (P6)
6757---System error
6758---Comms fault between I/C and O/C
6761---R22 R/A thermistor fault (P1)
6762---R22 TH2 fault check resistance (P2)
6763---R22 Comms fault between I/C and O/C
6764---R22 drain fault (P4)
6765---R22 drain fault (P5)
6766---R22 frost protection at I/C (P6)
6767---R22 comms fault between I/C and O/C
6771---K abnormality - high pressure abnormality or low pressure abnormality
6772---K abnormality - inner thermostat function, discharge temperature abnormality,
shell thermostat function, over current protection
6773---K abnormality - radiator plate thermostat function
6774---K abnormality - outdoor thermistor abnormality
6775---K abnormality - pressure sensor abnormality, indoor/outdoor communication error
6776---K abnormality - over current shut-off
6777---K abnormality - system error
6778---K abnormality - normal
6779---K abnormality - refrigerant overcharge, abnormal voltage, abnormal CT sensor
6830---Comms fault between I/C and R/C check connections to MA R/C and check for 12Vdc check R/C not set sub controller
6831--xMA R/C communication fault - check connections on TB15 or that the controller was removed while the I/C was powered
6832-xMA controller comms fault - check cable length no bigger than 500m, check connection and type of cable used, check R/C not set sub on field settings
6833--x
6834--x
6840---A-Control E6/E8 fault - see MR slim P series A fault codes list.
6841---A-Control E7/E9 fault - see MR slim P series A fault codes list.
6844---A-Control EA fault - see MR slim P series A fault codes list.
6845---A-Control Eb fault - see MR slim P series A fault codes list.
6846---A-Control EC fault - see MR slim P series A fault codes list.
7100xxxOver capacity - (R2 150% index exceeded) (Y 130% index exceeded)
7101xxxCapacity setting error - SW2 set wrong on indoors, SW5 on YHMA outdoor, (SW3-10 on older kit)
7102xxxError in number of connected units - loss of M-Net voltage (short or break), no power to BC, wrong SW5 setting on box, wrong box type
7105xxxAddress setting error - OC or BC addressed wrong
7106-xxAttribute setting error - SW3-1 setting on a GUF
7107xxxPort setting error - check if too much capacity on a single port, wiring SW2 setting, wrong SW14 setting or wrong units on a box when using multiple boxes
7110--xCheck SW5-7 is correctly set
7111xxxRemote control sensor fault - SW1 - 1 on and no controllers fitted or faulty remote controller
7113--xFunction setting error - wrong SW5 setting or wrong resistors fitted on YHM-A
7117--xModel setting error - SW5 set wrong or wrong resistors in
7130-xxIncompatible equipment on M-Net - check split with MAC 399 wired onto the TB5 line TB5 line, not the TB7

Mitsubishi Adns Codes Download Pc

  • View and Download Mitsubishi Electric FR - F700 programming manual online. PLC FUNCTION PROGRAMMING MANUAL. FR - F700 Inverter pdf manual download. Also for: Fr-f700.
  • Oct 28, 2011  Unlocking a Mitsubishi radio code after battery has been disconnected. How to enter the code. If you don't have the code, call a dealer and ask for the parts department (not service).
  • Applies to: Most vehicles 2002 model year and older.As part of the radio's anti-theft system, the radio disables itself when it loses power from the vehicle's battery. If the radio display indicates 'CODE' or 'OFF,' then the radio security code must be entered into the radio in order for the radio to work.